{"id":3144,"date":"2026-01-10T21:48:49","date_gmt":"2026-01-10T13:48:49","guid":{"rendered":"https:\/\/baldor-air.com\/?p=3144"},"modified":"2026-01-10T21:48:54","modified_gmt":"2026-01-10T13:48:54","slug":"10-precautions-to-follow-before-retrofitting-a-screw-air-compressor-with-a-vfd","status":"publish","type":"post","link":"https:\/\/baldor-air.com\/ja\/10-precautions-to-follow-before-retrofitting-a-screw-air-compressor-with-a-vfd\/","title":{"rendered":"10 Precautions to Follow Before Retrofitting a Screw Air Compressor with a VFD"},"content":{"rendered":"<p>Retrofitting screw air compressors with a <strong><a href=\"https:\/\/baldor-air.com\/ja\/%e5%b7%a5%e6%a5%ad%e7%94%a8%e3%82%a8%e3%82%a2%e3%83%bc%e3%82%b3%e3%83%b3%e3%83%97%e3%83%ac%e3%83%83%e3%82%b5%e3%83%bc\/\">Variable Frequency Drive (VFD)<\/a><\/strong> has become a mainstream solution to reduce energy consumption, especially in facilities where compressors account for a significant portion of total electricity usage.<\/p>\n\n\n\n<p>Since screw compressors are <strong>high-power, long-running<\/strong> systems, upgrading to a frequency-controlled solution offers great potential for <strong>energy savings and optimized performance<\/strong>. However, before proceeding with a VFD retrofit, several technical aspects must be carefully considered to ensure <strong>safe, efficient, and reliable operation<\/strong>.<\/p>\n\n\n\n<p>In this article, we outline <strong>10 key precautions<\/strong> you should take before converting your screw air compressor to variable frequency control.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h3 class=\"wp-block-heading\">\u2699\ufe0f <strong>1. Minimize Modifications to Existing Electrical Circuits<\/strong><\/h3>\n<\/div>\n<\/div>\n\n\n\n<p>Preserve the integrity of both the <strong>main power circuit<\/strong> and the <strong>control circuit<\/strong>. Avoid extensive rewiring. This allows the compressor to switch back to its <strong>original operating mode<\/strong> in case of VFD failure or maintenance, without the need to reprogram the PLC.<\/p>\n\n\n\n<p>\ud83d\udd17 <em>Explore: <a href=\"https:\/\/baldor-air.com\/ja\/%e3%82%aa%e3%82%a4%e3%83%ab%e3%83%95%e3%83%aa%e3%83%bc%e3%82%b9%e3%82%af%e3%83%aa%e3%83%a5%e3%83%bc%e3%82%a8%e3%82%a2%e3%82%b3%e3%83%b3%e3%83%97%e3%83%ac%e3%83%83%e3%82%b5%e3%83%bc\/\">Screw Compressor Control Systems<\/a><\/em><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h3 class=\"wp-block-heading\">\u26a1 <strong>2. Control VFD Start Signal via Star-Delta Contactor<\/strong><\/h3>\n<\/div>\n<\/div>\n\n\n\n<p>\u3092\u78ba\u8a8d\u3059\u308b\u3002 <strong>start signal for the VFD<\/strong> is controlled by the delta contactor (KM1) in a star-delta starter. This prevents the VFD from activating while still in the star connection phase.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h3 class=\"wp-block-heading\">\u23f1\ufe0f <strong>3. Delay Relay Must Exceed VFD Start Time<\/strong><\/h3>\n<\/div>\n<\/div>\n\n\n\n<p>Set the <strong>time-delay relay (JS)<\/strong> to a value <strong>greater than or equal to the VFD start time<\/strong>. This ensures that the compressor starts without load and avoids abrupt torque spikes.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h3 class=\"wp-block-heading\">\u23ec <strong>4. Enable VFD\u2019s Low-Frequency Stop Function<\/strong><\/h3>\n<\/div>\n<\/div>\n\n\n\n<p>Utilize the VFD\u2019s <strong>delayed stop at lower frequency<\/strong> to ensure smooth shutdown and to reduce mechanical stress on the system.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h3 class=\"wp-block-heading\">\ud83c\udf9a\ufe0f <strong>5. Set a Safe Minimum Frequency (\u226535 Hz)<\/strong><\/h3>\n<\/div>\n<\/div>\n\n\n\n<p>A frequency setpoint below 35 Hz may cause <strong>oil separation failure<\/strong>, leading to <strong>oil leakage<\/strong> due to insufficient centrifugal force in the oil-air separator. Adjust the <strong>lower frequency limit<\/strong> based on your compressor\u2019s specific wear level and design characteristics.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"847\" height=\"525\" src=\"https:\/\/baldor-air.com\/wp-content\/uploads\/2025\/06\/Variable-Frequency-Drive-VFD-1.jpg\" alt=\"variable frequency drive (vfd)\" class=\"wp-image-3145\" srcset=\"https:\/\/baldor-air.com\/wp-content\/uploads\/2025\/06\/Variable-Frequency-Drive-VFD-1.jpg 847w, https:\/\/baldor-air.com\/wp-content\/uploads\/2025\/06\/Variable-Frequency-Drive-VFD-1-300x186.jpg 300w, https:\/\/baldor-air.com\/wp-content\/uploads\/2025\/06\/Variable-Frequency-Drive-VFD-1-768x476.jpg 768w, https:\/\/baldor-air.com\/wp-content\/uploads\/2025\/06\/Variable-Frequency-Drive-VFD-1-18x12.jpg 18w\" sizes=\"(max-width: 847px) 100vw, 847px\" \/><figcaption class=\"wp-element-caption\">variable frequency drive (vfd)<\/figcaption><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h3 class=\"wp-block-heading\">\ud83d\udca1 <strong>6. Choose a VFD with a Higher Power Rating<\/strong><\/h3>\n<\/div>\n<\/div>\n\n\n\n<p>Select a VFD that is <strong>one size larger<\/strong> than the compressor motor\u2019s rated power to avoid <strong>frequent tripping during startup<\/strong> and to handle startup current peaks.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h3 class=\"wp-block-heading\">\ud83e\uddf2 <strong>7. Add an Output AC Reactor to Filter Harmonics<\/strong><\/h3>\n<\/div>\n<\/div>\n\n\n\n<p>Install an <strong>AC output reactor<\/strong> to filter out high-frequency harmonics from the VFD output. This reduces <strong>electromagnetic interference (EMI)<\/strong> \u305d\u3057\u3066 <strong>noise<\/strong>, and extends the life of the motor insulation.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h3 class=\"wp-block-heading\">\ud83d\udccd <strong>8. Proper Installation of Pressure Sensors<\/strong><\/h3>\n<\/div>\n<\/div>\n\n\n\n<p>Install pressure sensors <strong>close to the compressor<\/strong>\u305d\u3057\u3066 <strong>before any filters or valves<\/strong>. Do not place any shut-off valves between the compressor and the sensor. Retain the original <strong>mechanical pressure cut-off switch<\/strong> as a backup to ensure safety and prevent overpressure accidents.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h3 class=\"wp-block-heading\">\ud83d\udd27 <strong>9. Adjust System Pressure Control Logic<\/strong><\/h3>\n<\/div>\n<\/div>\n\n\n\n<p>After the VFD retrofit, lower the system\u2019s supply pressure if possible, and switch from a <strong>high-pressure, variable-flow<\/strong> setup to a <strong>constant-pressure, variable-flow<\/strong> strategy. This enhances energy efficiency while maintaining a stable supply.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h3 class=\"wp-block-heading\">\ud83d\udd01 <strong>10. Retain Dual Control Modes: VFD and Direct Line<\/strong><\/h3>\n<\/div>\n<\/div>\n\n\n\n<p>Design the control system with both <strong>VFD and direct line (power frequency)<\/strong> operation options. If the VFD fails or triggers a protective stop, the system should be able to <strong>automatically switch to bypass mode<\/strong> to maintain production uptime.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h3 class=\"wp-block-heading\">\u2705 <strong>\u6700\u7d42\u7684\u306a\u611f\u60f3<\/strong><\/h3>\n<\/div>\n<\/div>\n\n\n\n<p>A well-executed VFD retrofit on a <a href=\"https:\/\/baldor-air.com\/ja\/%e3%82%aa%e3%82%a4%e3%83%ab%e3%83%95%e3%83%aa%e3%83%bc%e3%82%b9%e3%82%af%e3%83%aa%e3%83%a5%e3%83%bc%e3%82%a8%e3%82%a2%e3%82%b3%e3%83%b3%e3%83%97%e3%83%ac%e3%83%83%e3%82%b5%e3%83%bc\/\">\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30a2\u30b3\u30f3\u30d7\u30ec\u30c3\u30b5\u30fc<\/a> can result in <strong>significant energy savings, quieter operation, and extended equipment life<\/strong>. However, skipping these critical precautions may cause startup problems, sensor inaccuracies, or even safety hazards.<\/p>\n\n\n\n<p>For a successful upgrade, always work with professional technicians and refer to manufacturer specifications. Baldor provides advanced solutions including <strong>intelligent VFD control, permanent magnet compressors<\/strong>, and system-level energy audits.<\/p>","protected":false},"excerpt":{"rendered":"<p>Retrofitting screw air compressors with a Variable Frequency Drive (VFD) has become a mainstream solution to reduce energy consumption, especially in facilities where compressors account for a significant portion of total electricity usage. Since screw compressors are high-power, long-running systems, upgrading to a frequency-controlled solution offers great potential for energy savings and optimized performance. However, before proceeding with a VFD retrofit, several technical aspects must be carefully considered to ensure safe, efficient, and reliable operation. In this article, we outline 10 key precautions you should take before converting your screw air compressor to variable frequency control. \u2699\ufe0f 1. Minimize Modifications to Existing Electrical Circuits Preserve the integrity of both the [&hellip;]<\/p>","protected":false},"author":1,"featured_media":3145,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","footnotes":""},"categories":[32],"tags":[266,265,101,239],"class_list":{"0":"post-3144","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-blog","8":"tag-baldor-air-compressor-vfd-conversion","9":"tag-energy-saving-compressor-solutions","10":"tag-screw-air-compressors","11":"tag-variable-frequency-drive-vfd"},"_links":{"self":[{"href":"https:\/\/baldor-air.com\/ja\/wp-json\/wp\/v2\/posts\/3144","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/baldor-air.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/baldor-air.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/baldor-air.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/baldor-air.com\/ja\/wp-json\/wp\/v2\/comments?post=3144"}],"version-history":[{"count":1,"href":"https:\/\/baldor-air.com\/ja\/wp-json\/wp\/v2\/posts\/3144\/revisions"}],"predecessor-version":[{"id":3146,"href":"https:\/\/baldor-air.com\/ja\/wp-json\/wp\/v2\/posts\/3144\/revisions\/3146"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/baldor-air.com\/ja\/wp-json\/wp\/v2\/media\/3145"}],"wp:attachment":[{"href":"https:\/\/baldor-air.com\/ja\/wp-json\/wp\/v2\/media?parent=3144"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/baldor-air.com\/ja\/wp-json\/wp\/v2\/categories?post=3144"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/baldor-air.com\/ja\/wp-json\/wp\/v2\/tags?post=3144"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}